Manages the Power and Data supplied down a CAT5e/6 cable from the Midspan Bridge

Lock Manager/Power Adaptor

The Power Adapter/Lock Manager circuit board has a small footprint and is designed to be mounted with the Electric Strike. Alternatively it can be housed together with the “Press to Exit” switch in a half gang electrical wall box.

It performs the following functions:

  • Breaks out the power and data supplied down a standard CAT5e cable by a Borer Midspan Bridge
  • Monitors door status settings (door open, lock status and exit request button pressed)
  • Manages the power supplied to operate a solenoid operated door lock or strike. These need an initial high current to engage the solenoid and then a reduced static current to maintain it. The power delivered by most systems is not current restricted which will cause the lock, after it has been switched, to continue to consume power. The extra energy consumed raises the temperature of the solenoid. By managing and limiting the power delivered, less heat is generated. As a result, less energy is used and the lock is not stressed, extending its operational lifespan.

Power over CAT5e cable technology is used to power equipment where it is inconvenient, expensive or not possible to provide a separate mains power outlet. It transmits electrical power and data to devices, such as card readers and electric door locks, over standard CAT5e cable.

This solution requires two components as follows:

  • A Midspan Bridge at the source, which injects power into a standard CAT5e cable system without affecting the data
  • A Power Adapter at the destination, which splits power and data for delivery to local devices.

The power management chipset employed (IEEE 802.3af standard), is designed for Power over Ethernet applications, providing protection against short circuit, polarity reversal and the accidental connection of non-compliant equipment.

For door access control applications the Power Adapter/Lock Manager is located on the secure side, either in the "Press to Exit" switch housing or installed into the door jam above the Electric Strike.

Communications between the Lock Manager and Card Reader is via a four core cable which supplies encoded data and power. This enhances security by removing the opportunity to gain access by dismantling the card access reader head and shorting out the lock or power supply cable ends.

Benefits:

  • Enhances Security preventing door access by tampering with the card access reader head or controller
  • Safeguards the Electrical Equipment connected to the circuit by only supplying power following device identification and evaluation
  • Protects the CAT5e Cable by measuring the energy delivered providing a 48 Volts current limited power source
  • Reduces Equipment Cost by eliminating the requirement for local main outlets, power supply and battery at every door
  • Reduces Installation Cost by eliminating the local mains wiring, which in most countries, for legal or insurance reasons, has to be installed by a qualified and/or licensed electrician
  • Up to 80% Reduction in Energy Consumption by managing the power being supplied to operate the electric door release

Part No. 04-136 Standard Lock Manager
Part No. 04-139 Middle of the Line Lock Manager

Download Datasheet

Technical:

  • Installation: For door access control applications, the Lock Manager is located on the secure side, either in the "Press to Exit" swtich housing or installed into the door jam above the electric lock or strike
  • Dimensions: 66 x 32 x 15mm
  • Weight: 24g
  • Diagnostic Indicators: CAN TX, CAN RX, CAN Fault
  • CAN Network/Network Connection: 1 channel CAN, ISO 11898 standard for serial data communications
  • Transmission Protocol: CSMA-CA (Carrier Sense Multiple Access with Collision Avoidance) 125kbps
  • Operating Temperature Range: -20 to 60C (-4 to 140 F)
  • Cable Type: Point to oint connection using CAT5e/6 Cable
  • Power/Data Delivery: Max. 13.5 Watts, 48 Volts, Max. 300m cable length
  • Inputs: 4 state supervised inputs, door monitor, REX and TAMPER/Spare
  • Alarm Reporting: Door Ajar, Door Forced, Tamper, Egress Made (Handle or Push to Exit Switch)

Borer's Power over Ethernet Access Control
Door Reader Installation Part 3 of 5

Click here to view all Borer tutorial videos